The rule most of the region starts from
Idaho uses the International Residential Code and International Building Code statewide, and cities and counties enforce and amend them. Teton County, Wyoming and the Town of Jackson run their own building departments under the same model codes. In both model codes the starting point is the same:
- Exempt from a permit: a retaining wall not over 4 feet, measured from the bottom of the footing to the top of the wall, that does not support a surcharge (IRC R105.2, IBC 105.2).
- Engineered design: a wall retaining more than 48 inches of unbalanced fill must be designed against overturning, sliding, excessive foundation pressure and water uplift (IRC R404.4).
Any jurisdiction can tighten this, add grading or setback rules, or measure height differently. Treat the 4-foot line as the starting question, not the answer.
The questions to ask before you dig
- Who has my parcel? Inside city or town limits it is usually the city or town; outside them, the county.
- How do you measure the height? From the bottom of the footing or from grade. Is a crushed-stone leveling pad the footing?
- Is anything a surcharge? A driveway, parking, a building, a slope above the wall, or a fence or guardrail on top.
- Are there property-line, setback or grading rules? Walls on a lot line or in a drainage path can trigger them.
- Do terraced walls count as one wall? Two short walls close together can be treated as one tall one.
Bonneville County: Idaho Falls, Ammon and the county
For a lot inside Idaho Falls or Ammon city limits, call the city's building department. For unincorporated Bonneville County, call the county. Walls around Idaho Falls run from residential landscape walls to driveway grade changes and commercial site work. A wall holding up a driveway or parking carries a surcharge whatever its height.
Teton County, Idaho: Driggs, Victor and Tetonia
Start with the Teton County, Idaho building department and ask whether your address is theirs or the city's. Sloped lots are common on the Teton side, and a slope rising above the wall is a surcharge.
Teton County, Wyoming: Jackson and Wilson
Inside the Town of Jackson, ask the town. Elsewhere in the county, ask Teton County. Expect to need a stamped design for any wall over 4 feet or carrying a driveway or structure.
What a permit application usually needs
- A site plan showing the wall's location, length, height and what is above and below it.
- For a wall over 4 feet or with a surcharge: a design and section stamped by a professional engineer licensed in that state.
- The block's technical data. VertiCore supplies the Verti-Block® Design Manual, cut sheets and engineering submittals for a project. Cut sheets and typical sections are on the resources page, and the rest is a request away.
What a Verti-Block wall looks like on paper
The typical section an engineer starts from: block on a crushed-stone leveling pad at least 6 inches deep, cores filled with clean 1-inch crushed stone as each course is set, a 5° batter (2-3/16 inches of setback per 24-inch course), perforated drain pipe at the base, nonwoven geotextile against the native soil, compacted native backfill, about 8 inches of fill over the top block, and ground sloped at least 2% away from the wall. The engineer sets embedment, base and reinforcement for the actual site. See how tall a Verti-Block wall can be.